Mitsubishi Electric
NV32-SVF3P30A30
Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB) - high-speed type - Mitsubishi (Japan series - NV-S (standard class) harmonic surge ready) - 3-poles (3P) - Rated current 30A - Residual current sensitivity 30mA - Short circuit breaking capacity (Icu) 5kA (400Vac; IEC60947) - Thermal-Magnetic (fixed) trip unit - Front lugs or bars connection connection
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
Brand
SKU
NV32-SVF3P30A30
Online Price
$209.07
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
NV32-SVF3P30A30Mitsubishi Electric - Japan series - NV-S (standard class) harmonic surge ready
Description
Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB) - high-speed type - Mitsubishi (Japan series - NV-S (standard class) harmonic surge ready) - 3-poles (3P) - Rated current 30A - Residual current sensitivity 30mA - Short circuit breaking capacity (Icu) 5kA (400Vac; IEC60947) - Thermal-Magnetic (fixed) trip unit - Front lugs or bars connection connection
Specifications
Primary brand
Mitsubishi
Main function
Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / ELCB
Product series / family name
Japan series
Sub-range name
NV-S (standard class) harmonic surge ready
Functions
Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB)
Design
high-speed type
Poles
3-poles (3P)
Rated current
30A
Trip current rating
30 AT
Frame current rating
30 AF
Residual current sensitivity
30mA
Rated impulse voltage (Uimp)
6 kV
Connection type
Front lugs or bars connection
Ultimate short circuit current breaking capacity (Icu)
7.5kA (100Vac; IEC60947)
7.5kA (200Vac; IEC60947)
7.5kA (230Vac; IEC60947)
5kA (400Vac; IEC60947)
5kA (415Vac; IEC60947)
2.5kA (440Vac; IEC60947)
7.5kA (200Vac; IEC60947)
7.5kA (230Vac; IEC60947)
5kA (400Vac; IEC60947)
5kA (415Vac; IEC60947)
2.5kA (440Vac; IEC60947)
Service short circuit current breaking capacity (Ics)
7.5kA (100Vac)
7.5kA (200Vac)
7.5kA (230Vac)
5kA (400Vac)
5kA (415Vac)
2.5kA (440Vac)
7.5kA (200Vac)
7.5kA (230Vac)
5kA (400Vac)
5kA (415Vac)
2.5kA (440Vac)
Service short circuit current breaking capacity as a percentage of Icu (Ics%)
(400Vac) 100 %
Trip unit type
Thermal-Magnetic (fixed)
Protection functions
Thermal protection (Overload)
Magnetic protection (Short-circuit)
Earth leakage protection
Magnetic protection (Short-circuit)
Earth leakage protection
Protection settings
Thermal protection (Overload) -- tripping threshold fixed at 30A
Mounting mode
Surface mounting (or DIN rail with optional adapter)
Dimensions
W54mm x H100mm x D90mm
Electrical durability (with load)
(440Vac) 6000 operations
Mechanical durability (at no load)
10000 operations
Utilisation category
A
Manufacturer product status
Commercialized
Equivalent to
NV32SVF3P30A30
Rated Voltage (AC) - Phase-to-phase
100-440 V
Compliant with standard(s)
IEC 60947-2 2nd edition
GB14048.2
JIS C8201-2-1 Ann.1 Ann.2
TUV approval CE marking
CCC recognized
GB14048.2
JIS C8201-2-1 Ann.1 Ann.2
TUV approval CE marking
CCC recognized
Degree of pollution
2
Related Documents
Name | Last Update | Language |
---|---|---|
Mitsubishi - Circuit breaker Japan series - Singapore - Catalog.pdf | 26 Feb 2021 | English (US) |