Mitsubishi Electric
NF100-HRU3P60AY
Moulded / Molded Case Circuit Breaker (MCCB) with pre-installed auxiliary sw. + vertical lead-wire term. block - Mitsubishi (UL 489 Listed MCCBs - NF-H (high-performance class)) - 3-poles (3P) - Rated current 60A - Short circuit breaking capacity (Icu) 25kA (400Vac; IEC60947) - Short circuit current rating 18kA (480Vac; UL489) - Thermal-Magnetic (fixed) trip unit - Front lugs or bars connection connection
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
Brand
SKU
NF100-HRU3P60AY
Online Price
$429.25
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
NF100-HRU3P60AYMitsubishi Electric - UL 489 Listed MCCBs - NF-H (high-performance class)
Description
Moulded / Molded Case Circuit Breaker (MCCB) with pre-installed auxiliary sw. + vertical lead-wire term. block - Mitsubishi (UL 489 Listed MCCBs - NF-H (high-performance class)) - 3-poles (3P) - Rated current 60A - Short circuit breaking capacity (Icu) 25kA (400Vac; IEC60947) - Short circuit current rating 18kA (480Vac; UL489) - Thermal-Magnetic (fixed) trip unit - Front lugs or bars connection connection
Specifications
Primary brand
Mitsubishi
Main function
Moulded Case Circuit Breaker (MCCB)
Product series / family name
UL 489 Listed MCCBs
Sub-range name
NF-H (high-performance class)
Functions
Moulded / Molded Case Circuit Breaker (MCCB)
Design
pre-installed auxiliary sw.
vertical lead-wire term. block
vertical lead-wire term. block
Poles
3-poles (3P)
Rated current
60A
Trip current rating
60 AT
Frame current rating
100 AF
Rated insulation voltage (Ui)
500 V
Connection type
Front lugs or bars connection
Short circuit breaking rating
50kA (240Vac; UL489)
18kA (480Vac; UL489)
18kA (480Vac; UL489)
Ultimate short circuit current breaking capacity (Icu)
50kA (230Vac; IEC60947)
25kA (400Vac; IEC60947)
25kA (415Vac; IEC60947)
25kA (440Vac; IEC60947)
18kA (500Vac; IEC60947)
25kA (400Vac; IEC60947)
25kA (415Vac; IEC60947)
25kA (440Vac; IEC60947)
18kA (500Vac; IEC60947)
Service short circuit current breaking capacity (Ics)
25kA (230Vac)
13kA (400Vac)
13kA (415Vac)
13kA (440Vac)
9kA (500Vac)
13kA (400Vac)
13kA (415Vac)
13kA (440Vac)
9kA (500Vac)
Service short circuit current breaking capacity as a percentage of Icu (Ics%)
(400Vac) 53 %
Trip unit type
Thermal-Magnetic (fixed)
Protection functions
Thermal protection (Overload)
Magnetic protection (Short-circuit)
Magnetic protection (Short-circuit)
Protection settings
Thermal protection (Overload) -- tripping threshold fixed at 60A
Dimensions
W75mm x H120mm x D102mm
Manufacturer product status
Commercialized
Equivalent to
NF100HRU3P60AY
Rated Voltage (AC) - Phase-to-phase
480 V
Compliant with standard(s)
IEC 60947-2
EN 60947-2
UL 489
CSA C22.2 No.5-02
EN 60947-2
UL 489
CSA C22.2 No.5-02
Benefits
These have one of the smallest sizes in the industry for items supporting 480V and contribute to the design of more compact machinery.
They can be used on 480Vac (delta) circuits. (Relevant models - NF100-HRU; NV100-HRU type)
There is simultaneous support for various overseas standards and simultaneous marking (UL-cUL-CE-CCC).
The breaker related regulations of North America; Europe; China and Japan are supported.
Earth leakage protection for inverter and servo circuits has advanced even further.
They can be used on 480Vac (delta) circuits. (Relevant models - NF100-HRU; NV100-HRU type)
There is simultaneous support for various overseas standards and simultaneous marking (UL-cUL-CE-CCC).
The breaker related regulations of North America; Europe; China and Japan are supported.
Earth leakage protection for inverter and servo circuits has advanced even further.
Related Documents
Name | Last Update | Language |
---|---|---|
Mitsubishi - Low-voltage power distribution products - Catalog.pdf | 26 Feb 2021 | English (US) |
Mitsubishi - UL 489 Listed Molded Case Circuit Breakers SMU SRU and HRU series - Catalog.pdf | 26 Feb 2021 | English (US) |